Skip to main content
DNA Labs India

Angiotensin II Test

DNA Labs India | ISO 9001:2015 Certified

Angiotensin II Test

Short Name: Angiotensin II

Also known as: Angiotensin II Blood Test, Angiotensin II Level Test, Angiotensin II Serum Test, RAAS Angiotensin II Test

Angiotensin II Test test available at DNA Labs India for ₹13,000. Uses Radioimmunoassay on Plasma samples. Results in Samples are dispatched to the reference laboratory by the 7th of each month. Results are available 2-3 weeks after sample dispatch and can be accessed through the DNA Labs India online portal, email, or WhatsApp.. Free home collection in 300+ cities across India.

Send-Out TestAdults🏠 Home Collection

🩺 Medically Reviewed By

Overview

The Angiotensin II test is primarily used to evaluate the function of the renin-angiotensin-aldosterone system (RAAS) and to help diagnose conditions related to abnormal blood pressure regulation and fluid-electrolyte balance. It assists physicians in identifying the underlying causes of resistant hypertension, differentiating between primary and secondary hypertension, assessing suspected renal artery stenosis, monitoring the effectiveness of RAAS-modulating medications such as ACE inhibitors and angiotensin II receptor blockers (ARBs), and evaluating electrolyte disturbances involving sodium and potassium. The test is also used in the investigation of renal function disorders and in the comprehensive assessment of cardiovascular health when RAAS dysfunction is clinically suspected.

Test Code
133
ICD Code
I10
Price
₹13,000
Sample Type
Plasma
Result Time
Samples are dispatched to the reference laboratory by the 7th of each month. Results are available 2-3 weeks after sample dispatch and can be accessed through the DNA Labs India online portal, email, or WhatsApp.
Fasting Required
No
Method
Radioimmunoassay
Step 1

Sample Collection

Inform your physician about all medications you are currently taking, especially ACE inhibitors, ARBs, diuretics, beta-blockers, NSAIDs, or corticosteroids. Your doctor may advise temporarily discontinuing certain medications before the test. Maintain a controlled sodium diet as instructed. A duly filled Test Send Out Consent Form (Form 35) is mandatory. No routine fasting is required unless specifically advised by your physician.

Method: Venipuncture

Step 2

Laboratory Analysis

A trained phlebotomist will collect approximately 2 mL of blood from a vein in your arm using a standard venipuncture technique. The blood is transferred into a Lavender Top (EDTA) tube. The patient's posture (supine or upright) at the time of collection should be documented, as it directly affects results.

Step 3

Report Delivery

Apply gentle pressure to the puncture site with cotton or a bandage for a few minutes. Mild bruising at the site is normal and typically resolves on its own. Resume normal activities unless advised otherwise. The sample will be shipped refrigerated or frozen to the reference laboratory for analysis.

Timeline: Samples are dispatched to the reference laboratory by the 7th of each month. Results are available 2-3 weeks after sample dispatch and can be accessed through the DNA Labs India online portal, email, or WhatsApp.

Patient Instructions

1
Before the Test:Prior to the Angiotensin II test, patients should inform their physician about all current medications, including over-the-counter drugs and supplements. Certain medications such as ACE inhibitors, ARBs, diuretics, beta-blockers, NSAIDs, and corticosteroids can significantly affect results and may need to be temporarily discontinued under medical supervision. A controlled sodium diet for at least 3 days before the test is recommended unless otherwise directed. A duly filled Test Send Out Consent Form (Form 35) is mandatory.
2
During the Test:During the test, a trained phlebotomist will collect approximately 2 mL of blood from a vein in your arm using standard venipuncture. The blood sample is placed into a Lavender Top (EDTA) tube. The procedure typically takes less than 5 minutes. Your posture at the time of collection (supine or upright) will be recorded as it influences results.
3
After the Test:After the blood draw, gentle pressure is applied to the puncture site. Mild bruising may occur and usually resolves within a few days. Normal activities can be resumed immediately. The sample will be shipped under appropriate refrigerated or frozen conditions to the reference laboratory. Results are typically available within 2-3 weeks after sample receipt by the reference laboratory.

About This Test

Who Should Get This Test

The Angiotensin II test is primarily used to evaluate the function of the renin-angiotensin-aldosterone system (RAAS) and to help diagnose conditions related to abnormal blood pressure regulation and fluid-electrolyte balance. It assists physicians in identifying the underlying causes of resistant hypertension, differentiating between primary and secondary hypertension, assessing suspected renal artery stenosis, monitoring the effectiveness of RAAS-modulating medications such as ACE inhibitors and angiotensin II receptor blockers (ARBs), and evaluating electrolyte disturbances involving sodium and potassium. The test is also used in the investigation of renal function disorders and in the comprehensive assessment of cardiovascular health when RAAS dysfunction is clinically suspected.

How to Prepare

  • A duly filled Test Send Out Consent Form (Form 35) is mandatory before sample collection
  • Inform the phlebotomist about your current posture status (supine or upright) for result interpretation
  • Inform your physician about all current medications before sample collection
  • Avoid strenuous physical activity for at least 30 minutes before sample collection
  • Maintain a normal sodium diet for at least 3 days before the test unless otherwise directed
  • Sample volume required: 2 mL (1 mL minimum) plasma collected in a Lavender Top (EDTA) tube

Doctor's Notes

Reviewed by — MBBS, MD (Biochemistry) · Reg. No. 21504

"The Angiotensin II test is an important diagnostic tool for evaluating the renin-angiotensin-aldosterone system (RAAS). It is particularly useful when investigating the underlying causes of resistant hypertension, suspected renal artery stenosis, or electrolyte imbalances. Elevated or suppressed Angiotensin II levels, when interpreted alongside renin and aldosterone values, can guide treatment decisions including the use of ACE inhibitors or ARBs. This test is typically ordered in conjunction with clinical assessment rather than as a standalone screening tool. Patients should consult their endocrinologist or treating physician to understand the implications of their results in the context of their overall health profile."

Last medically reviewed: September 7, 2026

Test Parameters & Specifications

Sample TypePlasma
Sample Volume2 mL (1 mL min.)
ContainerLavender Top (EDTA) tube
Collection MethodVenipuncture

Sample Stability

Room Temperature
Refrigerated (2-8°C)
Frozen (-20°C)
Sample Rejection Criteria:
  • Sample collected in incorrect tube type (non-EDTA)
  • Insufficient sample volume (less than 1 mL plasma)
  • Sample not shipped under appropriate temperature conditions
  • Missing or incomplete Test Send Out Consent Form (Form 35)
  • Sample received beyond the stability window
  • Hemolyzed or lipemic specimen

Understanding Your Results

The results of the Angiotensin II test provide valuable information about the activity of the renin-angiotensin-aldosterone system (RAAS). Interpretation must be performed by a qualified healthcare professional who considers the patient's clinical history, current medications, posture at the time of collection, sodium intake, and concurrent laboratory values including renin activity and aldosterone levels.
📊

High levels may indicate renovascular hypertension, renal artery stenosis, heart failure, cirrhosis with ascites, volume depletion, or a low-sodium diet. Elevated Angiotensin II stimulates aldosterone release, causing sodium retention and potassium loss.

📊

Low levels may suggest primary aldosteronism (Conn's syndrome) where autonomous aldosterone production suppresses renin and angiotensin II, or may result from high-sodium diet, use of ACE inhibitors or ARBs, or certain rare genetic conditions affecting RAAS components.

📊

Results within the reference range suggest normal RAAS function. However, clinical correlation is necessary as some conditions may present with normal Angiotensin II in the context of other abnormal findings.

⚠️ When to Consult a Doctor:

Consult your physician or endocrinologist if your Angiotensin II test results are outside the normal reference range, if you experience persistent high blood pressure that does not respond to treatment, recurrent episodes of dizziness or fainting, unexplained electrolyte imbalances, excessive thirst, signs of dehydration, or symptoms suggestive of kidney dysfunction. Your doctor will evaluate the results in conjunction with other clinical findings and recommend appropriate management or further testing.

Limitations

  • This is a send-out test; results are available only after 2-3 weeks from sample dispatch date (samples collected by the 7th of each month)
  • Angiotensin II levels fluctuate based on posture, sodium intake, and time of day, making standardization of collection conditions critical
  • Single measurement may not capture dynamic RAAS activity; clinical correlation is essential
  • Reference ranges may vary between laboratories due to differences in assay methodology
  • The test should be interpreted in conjunction with renin activity and aldosterone levels for comprehensive RAAS assessment
  • A duly filled Test Send Out Consent Form (Form 35) is mandatory for sample processing

Risks & Considerations

  • Minor bruising or hematoma at the venipuncture site
  • Slight pain or discomfort during blood draw
  • Rare risk of infection at the puncture site
  • Lightheadedness or dizziness during or after blood collection
  • No significant long-term risks associated with the test

Interfering Factors

  • Medications such as ACE inhibitors, ARBs, diuretics, beta-blockers, NSAIDs, and corticosteroids can significantly alter Angiotensin II levels
  • Sodium intake and dietary salt levels affect RAAS activity and test outcomes
  • Patient posture during sample collection (supine vs. upright) influences results
  • Pregnancy can physiologically elevate Angiotensin II levels
  • Dehydration or volume depletion may cause falsely elevated results
  • Recent blood transfusion or IV fluid administration may affect plasma composition

Compare With Similar Tests

TestAngiotensin II TestRenin Activity TestAldosterone TestRenin-Aldosterone Ratio (ARR)Serum Electrolytes (Sodium and Potassium)
ComparisonAngiotensin II TestThe Renin Activity Test measures plasma renin activity (PRA), which reflects the rate at which angiotensinogen is converted to angiotensin I. While the Angiotensin II test measures the end-product hormone, the renin test evaluates the initiating enzyme activity. Both tests are complementary and often ordered together to assess the full RAAS pathway.The Aldosterone Test measures aldosterone levels in blood or urine. Aldosterone is the downstream hormone stimulated by angiotensin II. While the Angiotensin II test evaluates the vasoconstrictive and signaling component of RAAS, the aldosterone test assesses the mineralocorticoid response. Both are used together to calculate the aldosterone-to-renin ratio (ARR) for primary aldosteronism screening.The ARR is a calculated ratio used as a screening tool for primary aldosteronism. Unlike the standalone Angiotensin II test, ARR combines aldosterone and renin measurements to detect autonomous aldosterone production. The Angiotensin II test provides additional information about RAAS activity that complements ARR findings.Serum electrolyte panels measure sodium and potassium levels directly. Elevated Angiotensin II typically promotes sodium retention and potassium excretion through aldosterone. Electrolyte testing is a routine first-line investigation that may prompt further RAAS-specific testing including the Angiotensin II test when abnormal patterns are detected.

Frequently Asked Questions

What is the Angiotensin II test?
The Angiotensin II test is a blood test that measures the level of angiotensin II, a hormone that is a key component of the renin-angiotensin-aldosterone system (RAAS). This hormone regulates blood pressure, fluid balance, and electrolyte homeostasis. The test helps evaluate conditions related to abnormal blood pressure regulation and renal function.
Why has my doctor ordered an Angiotensin II test?
Your doctor may order this test if you have resistant hypertension that is not responding to standard treatment, suspected renal artery stenosis, unexplained electrolyte imbalances involving sodium and potassium, suspected primary aldosteronism, or if there is a need to evaluate the function of the renin-angiotensin-aldosterone system in relation to renal or cardiovascular conditions.
What is the cost of the Angiotensin II test at DNA Labs India?
The cost of the Angiotensin II test at DNA Labs India is Rs 13000. This price includes free home sample collection across major cities in India, laboratory analysis, and online report delivery.
Does the Angiotensin II test require fasting?
Routine fasting is not mandatory for the Angiotensin II test. However, your physician may provide specific instructions regarding dietary sodium intake or medication adjustments before the test. Always follow your doctor's specific guidance.
What sample is required for the Angiotensin II test?
The test requires 2 mL (1 mL minimum) of plasma collected from a Lavender Top (EDTA) tube via standard venipuncture. The sample is shipped refrigerated or frozen to the reference laboratory for analysis.
How long does it take to get the Angiotensin II test results?
The Angiotensin II test is a send-out test. Samples are dispatched by the 7th of each month, and results are typically available within 2-3 weeks after sample dispatch. Results can be accessed via the online portal, email, or WhatsApp.
What do high Angiotensin II levels indicate?
Elevated Angiotensin II levels may indicate renovascular hypertension, renal artery stenosis, heart failure, liver cirrhosis with ascites, volume depletion, or dehydration. High levels reflect overactivation of the RAAS pathway, often in response to reduced renal perfusion or low blood pressure.
What do low Angiotensin II levels indicate?
Low Angiotensin II levels may suggest primary aldosteronism (Conn's syndrome), high sodium diet, or the use of medications that block the RAAS pathway such as ACE inhibitors or ARBs. Low levels indicate suppressed RAAS activity, which requires clinical correlation.
Can medications affect the Angiotensin II test results?
Yes, several medications can significantly affect Angiotensin II levels. These include ACE inhibitors, angiotensin II receptor blockers (ARBs), diuretics, beta-blockers, NSAIDs, and corticosteroids. Inform your physician about all current medications, and do not discontinue any medication without medical advice.
Is the Angiotensin II test available with home sample collection?
Yes, DNA Labs India offers free home sample collection for the Angiotensin II test across major cities in India, including Mumbai, Delhi, Bangalore, Hyderabad, Chennai, Kolkata, Pune, and many more. You can book online to schedule your home collection.
Is the Angiotensin II test covered under government health schemes?
Coverage for the Angiotensin II test under government health schemes such as PMJAY, CGHS, ECHS, and ESIC depends on the specific terms and eligibility criteria of each scheme. Patients are advised to check with their respective scheme offices or insurance providers for coverage confirmation.
Is a consent form required for the Angiotensin II test?
Yes, a duly filled Test Send Out Consent Form (Form 35) is mandatory for the Angiotensin II test. This is because the test is a send-out investigation where the blood sample is dispatched to a specialized external reference laboratory for analysis. The consent form must be completed before sample collection.
Worried about the process? Our certified phlebotomists collect thousands of samples every month across India. The process takes under 5 minutes and is virtually painless. Questions? Message us on WhatsApp — we're here 7 days a week.
For Hospitals & Clinics

Reference Laboratory Services

We serve as a reference laboratory for hospitals and clinics across India. Send samples from your facility with same-day pickup, priority processing, and results delivered through our online portal. Competitive institutional pricing available.

LIMS Integration

Your Data Privacy

Your medical data is protected under Indian law.

Stored in India: All patient records are stored on servers located in India. No data is transferred outside the country.

DPDP Act Compliant: Under the Digital Personal Data Protection Act 2023, you can request deletion of your records at any time by contacting support.

Book Your Test

Enter your details and we'll connect you within 15 minutes.

🧬

Quick Connect

Enter your mobile number and we’ll connect you with the team.

+91

✅ Connecting you now...

🔒 Your number is used to respond to this request.