Skip to main content
DNA Labs India

H. Influenza Viral Load Quantitative Test

DNA Labs India | ISO 9001:2015 Certified

H. Influenza Viral Load Quantitative Test

Short Name: H. Influenza Viral Load

Also known as: H. influenzae PCR, Haemophilus influenzae viral load, H. flu quantitative PCR

H. Influenza Viral Load Quantitative Test test available at DNA Labs India for ₹8,160. Uses Real Time PCR on CSF, Bronchial Swabs, Bronchial Lavage samples. Results in Reports are delivered within 3 working days. Email reports are sent within 36 hours after the test is completed, and phone support is available 24 hours.. Free home collection in 300+ cities across India.

Quantitative PCR🏠 Home Collection

🩺 Medically Reviewed By

Overview

The purpose of the H. Influenza Viral Load Quantitative Test is to detect and quantify the presence of Haemophilus influenzae DNA in clinical samples. It is used for: 1) Confirming active infection when culture is negative or inconclusive, 2) Assessing the severity of infection by measuring bacterial load, 3) Monitoring response to antibiotic therapy, 4) Detecting early relapse or treatment failure, 5) Guiding duration of therapy in invasive infections like meningitis or pneumonia.

Test Code
6150
CPT Code
87581
ICD Code
B96.3
Price
₹8,160
Sample Type
CSF, Bronchial Swabs, Bronchial Lavage
Result Time
Reports are delivered within 3 working days. Email reports are sent within 36 hours after the test is completed, and phone support is available 24 hours.
Fasting Required
No
Method
Real Time PCR
Step 1

Sample Collection

No special preparation is required. However, inform your doctor about any recent antibiotic use. A signed consent document is mandatory.

Method: Healthcare professional

Step 2

Laboratory Analysis

Sample collection (CSF, bronchial swab, or lavage) is performed by a trained healthcare professional under sterile conditions. You may experience mild discomfort depending on the sample type.

Step 3

Report Delivery

No specific precautions are needed. You can resume normal activities immediately. Results will be available within 3 working days.

Timeline: Reports are delivered within 3 working days. Email reports are sent within 36 hours after the test is completed, and phone support is available 24 hours.

Patient Instructions

1
Before the Test:No special preparation is required. However, inform your doctor about any recent antibiotic use. A signed consent document is mandatory.
2
During the Test:Sample collection (CSF, bronchial swab, or lavage) is performed by a trained healthcare professional under sterile conditions. You may experience mild discomfort depending on the sample type.
3
After the Test:No specific precautions are needed. You can resume normal activities immediately. Results will be available within 3 working days.

About This Test

Who Should Get This Test

The purpose of the H. Influenza Viral Load Quantitative Test is to detect and quantify the presence of Haemophilus influenzae DNA in clinical samples. It is used for: 1) Confirming active infection when culture is negative or inconclusive, 2) Assessing the severity of infection by measuring bacterial load, 3) Monitoring response to antibiotic therapy, 4) Detecting early relapse or treatment failure, 5) Guiding duration of therapy in invasive infections like meningitis or pneumonia.

How to Prepare

  • CSF: Collected via lumbar puncture by a physician
  • Bronchial swab: Inserted through the nose or mouth to collect secretions
  • Bronchial lavage: Performed during bronchoscopy under local anesthesia

Doctor's Notes

Reviewed by — MBBS, MD (Microbiology) · Reg. No. 27670

"Quantitative H. influenzae PCR is essential for monitoring bacterial load in invasive infections, guiding therapy duration, and detecting early treatment failure."

Last medically reviewed: September 7, 2026

Test Parameters & Specifications

Sample TypeCSF, Bronchial Swabs, Bronchial Lavage
Sample VolumeAs per specimen type
ContainerSterile container
Collection MethodHealthcare professional

Sample Stability

CSF: Stable for 24 hours at 2-8°C, for 1 week at -20°C
Swabs: Stable for 48 hours at 2-8°C, for 1 week at -20°C
Lavage: Stable for 24 hours at 2-8°C, for 1 week at -20°C
Sample Rejection Criteria:
  • Insufficient sample volume
  • Sample leaking or not in sterile container
  • Improper labeling
  • Delayed transport without proper temperature control

Understanding Your Results

The H. Influenza Viral Load Quantitative Test result should be interpreted in the context of the patient's clinical presentation, culture results, and other laboratory findings. A positive result with high viral load suggests active infection, while low levels may indicate colonization or early infection. Serial monitoring can help assess treatment efficacy.
📊

No H. influenzae DNA detected

Active infection unlikely; consider other etiologies

📊

H. influenzae DNA detected at low level

Possible colonization or early infection; correlate clinically

📊

H. influenzae DNA detected at high level

Active infection likely; initiate or adjust antibiotic therapy

⚠️ When to Consult a Doctor:

Consult your physician if you experience symptoms such as high fever, severe headache, stiff neck, difficulty breathing, or persistent cough, especially if you are immunocompromised or have been in contact with someone with H. influenzae infection. Early diagnosis and treatment are crucial to prevent complications.

Limitations

  • Test cannot differentiate between active infection and colonization
  • Quantification may not correlate with disease severity in all cases
  • Negative result does not completely rule out infection if sample quality is poor
  • Requires specialized equipment and trained personnel

Risks & Considerations

  • Lumbar puncture (for CSF) may cause headache, infection, or bleeding
  • Bronchoscopy (for lavage) may cause sore throat, cough, or minor bleeding
  • Swab collection may cause mild discomfort or gagging

Interfering Factors

  • Recent antibiotic therapy may reduce bacterial load, leading to false negatives
  • Contamination during sample collection can cause false positives
  • Improper storage or transport may degrade DNA, affecting results
  • Presence of PCR inhibitors in the sample (e.g., blood, mucus) can interfere with amplification

Compare With Similar Tests

TestH. Influenza Viral Load Quantitative TestCultureAntigen DetectionPCR (Qualitative)Quantitative PCR (This Test)
ComparisonH. Influenza Viral Load Quantitative Test

Frequently Asked Questions

What is the cost of the H. Influenza Viral Load Quantitative Test at DNA Labs India?
The test costs Rs 8160, which includes sample collection and report delivery.
What sample types are accepted for this test?
CSF, bronchial swabs, and bronchial lavage are accepted.
Is fasting required before the test?
No, fasting is not required.
How long does it take to get the results?
Reports are available on the 3rd working day after sample collection.
Is home sample collection available?
Yes, we offer free home sample collection for online bookings across major Indian cities.
What does a positive result mean?
A positive result indicates the presence of H. influenzae DNA. The viral load (copies/mL) helps determine if it is an active infection or colonization.
Can this test be used to monitor treatment?
Yes, serial testing can monitor the effectiveness of antibiotic therapy by tracking changes in bacterial load.
Are there any risks associated with sample collection?
Risks depend on the sample type. Lumbar puncture may cause headache or infection; bronchoscopy may cause sore throat or minor bleeding. These are rare and managed by professionals.
Do I need a doctor's prescription for this test?
Yes, a physician's prescription is recommended. You also need to sign a consent document and provide clinical history.
Is the test covered by insurance?
Coverage varies by insurance provider. Please check with your insurer or contact us for assistance.
What is the difference between this test and a culture?
This test uses PCR to detect and quantify bacterial DNA, which is faster and more sensitive than culture, especially after antibiotic use.
How accurate is the test?
The test is highly accurate with high sensitivity and specificity, performed in NABL-accredited labs using validated protocols.
Worried about the process? Our certified phlebotomists collect thousands of samples every month across India. The process takes under 5 minutes and is virtually painless. Questions? Message us on WhatsApp — we're here 7 days a week.

Related Tests

For Hospitals & Clinics

Reference Laboratory Services

We serve as a reference laboratory for hospitals and clinics across India. Send samples from your facility with same-day pickup, priority processing, and results delivered through our online portal. Competitive institutional pricing available.

LIMS Integration

Your Data Privacy

Your medical data is protected under Indian law.

Stored in India: All patient records are stored on servers located in India. No data is transferred outside the country.

DPDP Act Compliant: Under the Digital Personal Data Protection Act 2023, you can request deletion of your records at any time by contacting support.

Book Your Test

Enter your details and we'll connect you within 15 minutes.

🧬

Quick Connect

Enter your mobile number and we’ll connect you with the team.

+91

✅ Connecting you now...

🔒 Your number is used to respond to this request.