Metapneumonia Virus B Viral Load Quantitative Test
Short Name: MPV-B Viral Load
Also known as: MPV-B Quantitative PCR, Human Metapneumovirus B Viral Load
Metapneumonia Virus B Viral Load Quantitative Test test available at DNA Labs India for ₹8,500. Uses Real Time PCR on Bronchial Swab, Bronchial Lavage, Sputum, Nasopharyngeal (NP) aspirates and swabs in viral transport medium, or lung tissues samples. Results in Reports are delivered on the 4th working day. Email reports within 48 hours, phone within 36 hours.. Free home collection in 300+ cities across India.
🩺 Medically Reviewed By
Dr Kothari Ramesh Shantilal
Consultant Microbiologist · Reg: 27670
Last reviewed: September 7, 2026
Overview
The purpose of this test is to detect the presence of Metapneumonia Virus B and quantify the viral load in respiratory samples. It aids in confirming infection, evaluating disease severity, guiding treatment decisions, and monitoring the effectiveness of antiviral therapy.
- Test Code
- 6200
- CPT Code
- 87507
- ICD Code
- B97.89
- Price
- ₹8,500
- Sample Type
- Bronchial Swab, Bronchial Lavage, Sputum, Nasopharyngeal (NP) aspirates and swabs in viral transport medium, or lung tissues
- Result Time
- Reports are delivered on the 4th working day. Email reports within 48 hours, phone within 36 hours.
- Fasting Required
- No
- Method
- Real Time PCR
Sample Collection
No special preparation required. However, patients should provide clinical history and sign a consent document.
Method: Nasopharyngeal swab, bronchial swab, sputum collection, or bronchial lavage
Laboratory Analysis
Sample collection involves a nasal/throat swab or sputum collection. It may cause mild discomfort but is generally safe.
Report Delivery
No specific precautions. Patients can resume normal activities immediately.
Timeline: Reports are delivered on the 4th working day. Email reports within 48 hours, phone within 36 hours.
Patient Instructions
About This Test
Who Should Get This Test
The purpose of this test is to detect the presence of Metapneumonia Virus B and quantify the viral load in respiratory samples. It aids in confirming infection, evaluating disease severity, guiding treatment decisions, and monitoring the effectiveness of antiviral therapy.
How to Prepare
- Use sterile swabs and place in viral transport medium
- For sputum, collect early morning sample in sterile container
- Label the sample with patient ID and collection time
- Transport to laboratory at 2-8°C if delay expected
Doctor's Notes
Reviewed by Dr Kothari Ramesh Shantilal — MBBS, MD (Microbiology) · Reg. No. 27670
"Quantitative viral load testing for MPV-B is essential for monitoring disease severity, guiding antiviral therapy, and assessing treatment response, especially in immunocompromised patients."
Last medically reviewed: September 7, 2026
Test Parameters & Specifications
Sample Stability
- Insufficient sample volume
- Improper labeling
- Sample not in viral transport medium
- Sample leaked or contaminated
- Delayed transport without proper storage
Understanding Your Results
Not Detected
No MPV-B RNA found. Infection unlikely, but consider other pathogens.
Detected (low viral load)
Active infection with low viral burden. May indicate early infection or mild disease.
Detected (high viral load)
Active infection with high viral burden. Likely severe disease; monitor closely.
Consult a physician if you have persistent fever, cough, difficulty breathing, or if symptoms worsen. Early diagnosis can prevent complications.
Limitations
- ⚠Negative result does not rule out infection if sample quality is poor
- ⚠Viral load may not correlate with disease severity in all patients
- ⚠Test detects MPV-B only, not other respiratory pathogens
- ⚠Results should be interpreted in conjunction with clinical findings
Risks & Considerations
- ●Minimal risk of bleeding or infection at collection site
- ●Slight discomfort during swab collection
- ●Rarely, bronchial lavage may cause transient cough
Interfering Factors
- ●Improper sample collection or storage may degrade viral RNA
- ●Presence of inhibitors in the sample (e.g., blood, mucus) can affect PCR
- ●Recent antiviral therapy may reduce viral load
- ●Sample contamination can lead to false positives
Compare With Similar Tests
| Test | Metapneumonia Virus B Viral Load Quantitative Test | RSV PCR | Influenza A/B PCR | COVID-19 RT-PCR |
|---|---|---|---|---|
| Comparison | Metapneumonia Virus B Viral Load Quantitative Test |
Frequently Asked Questions
What is the cost of the Metapneumonia Virus B Viral Load Test?
How is the sample collected for this test?
Do I need to fast before the test?
How long does it take to get results?
Is home sample collection available?
What does a high viral load indicate?
Can this test detect other respiratory viruses?
Who should get this test?
Is the test covered by insurance?
What is the sample type for this test?
How accurate is the test?
Are there any risks associated with the test?
Related Tests
Reference Laboratory Services
We serve as a reference laboratory for hospitals and clinics across India. Send samples from your facility with same-day pickup, priority processing, and results delivered through our online portal. Competitive institutional pricing available.
Your Data Privacy
Your medical data is protected under Indian law.
✓ Stored in India: All patient records are stored on servers located in India. No data is transferred outside the country.
✓ DPDP Act Compliant: Under the Digital Personal Data Protection Act 2023, you can request deletion of your records at any time by contacting support.
Book Your Test
Enter your details and we'll connect you within 15 minutes.
