Phospholipid Antibodies Panel IgG & IgM Test
Short Name: Phospholipid Antibodies Panel
Also known as: APL Antibodies Panel, Antiphospholipid Antibody Panel, Phospholipid Antibodies IgG/IgM
Phospholipid Antibodies Panel IgG & IgM Test test available at DNA Labs India for ₹1,638. Uses Enzyme Immunoassay on Serum samples. Results in Reports are delivered the same day if the sample is received by 9 am, Monday through Saturday. Results are available online, via email, and on WhatsApp.. Free home collection in 300+ cities across India.
🩺 Medically Reviewed By
Dr Ramarao Paidisetty
Consultant Biochemist · Reg: 21504
Last reviewed: September 7, 2026
Overview
Testing for phospholipid antibodies is indicated in cases of unexplained arterial / venous thrombosis, pregnancy with unexplained fetal deaths, spontaneous abortions, presence of unexplained cutaneous circulatory disturbance like livedo reticularis and presence of systemic rheumatic disease like lupus erythematosus. This test is also used in cases of unexplained thrombocytopenia, hemolytic anemia & non-bacterial thrombotic endocarditis.
- Test Code
- 3553
- Price
- ₹1,638
- Sample Type
- Serum
- Result Time
- Reports are delivered the same day if the sample is received by 9 am, Monday through Saturday. Results are available online, via email, and on WhatsApp.
- Fasting Required
- No
- Method
- Enzyme Immunoassay
Sample Collection
No special preparation is required. You may eat, drink, and continue regular medications unless otherwise advised by your doctor.
Method: Blood draw from a vein
Laboratory Analysis
A healthcare professional will draw a blood sample from a vein in your arm. The entire procedure takes only a few minutes.
Report Delivery
You can resume normal activities immediately after the blood draw. Apply pressure on the puncture site to reduce bruising.
Timeline: Reports are delivered the same day if the sample is received by 9 am, Monday through Saturday. Results are available online, via email, and on WhatsApp.
Patient Instructions
About This Test
Who Should Get This Test
Testing for phospholipid antibodies is indicated in cases of unexplained arterial / venous thrombosis, pregnancy with unexplained fetal deaths, spontaneous abortions, presence of unexplained cutaneous circulatory disturbance like livedo reticularis and presence of systemic rheumatic disease like lupus erythematosus. This test is also used in cases of unexplained thrombocytopenia, hemolytic anemia & non-bacterial thrombotic endocarditis.
How to Prepare
- Serum is collected in a Serum Separator Tube (SST).
- Minimal sample volume: 1 mL serum.
- Ship refrigerated or frozen after collection.
Doctor's Notes
Reviewed by Dr Ramarao Paidisetty — MBBS, MD (Biochemistry) · Reg. No. 21504
"Phospholipid antibody testing is crucial for evaluating unexplained thrombosis and recurrent pregnancy loss. A positive result must be interpreted alongside clinical findings."
Last medically reviewed: September 7, 2026
Test Parameters & Specifications
Sample Stability
- Hemolyzed or lipemic samples
- Incorrectly labeled or unlabeled samples
- Samples not stored as required
Understanding Your Results
Negative
No significant IgG or IgM phospholipid antibodies were detected. This is a normal finding.
Moderate Positive
Moderate levels of antibodies were found. This may be transient; confirmatory testing after 12 weeks is recommended.
High Positive
High levels of IgG and/or IgM antibodies were found. This supports the diagnosis of antiphospholipid syndrome when clinical manifestations are present.
Consult a doctor if you have unexplained blood clots, recurrent pregnancy loss, or symptoms such as fatigue, skin rashes, joint pain, or swelling. Early diagnosis is important for managing autoimmune conditions.
Limitations
- ⚠A positive result alone does not confirm antiphospholipid syndrome; clinical criteria must also be met.
- ⚠Lupus anticoagulant is a separate functional test and is not included in this antibody panel.
- ⚠Antibody levels may fluctuate over time; repeat testing after 12 weeks is often required for persistent positivity.
Risks & Considerations
- ●Mild pain or discomfort at the needle site
- ●Bruising or swelling at the puncture site
- ●Rare risk of infection, which is minimized by using sterile equipment
Interfering Factors
- ●Recent acute infections or inflammation may cause transient false-positive results.
- ●Anticoagulant therapy, especially heparin, may interfere with the test.
- ●Hemolyzed, icteric, or lipemic samples may affect assay performance.
Frequently Asked Questions
What is the Phospholipid Antibodies Panel IgG & IgM test?
Why is this test done?
What is the cost of the Phospholipid Antibodies Panel IgG & IgM test?
Is fasting required for this test?
What does a positive result indicate?
What does a negative result mean?
What type of sample is required?
How soon will I get the report?
Is home sample collection available?
Who should get this test?
Are there any risks associated with the test?
Does medical insurance cover this test?
Related Tests
Reference Laboratory Services
We serve as a reference laboratory for hospitals and clinics across India. Send samples from your facility with same-day pickup, priority processing, and results delivered through our online portal. Competitive institutional pricing available.
Your Data Privacy
Your medical data is protected under Indian law.
✓ Stored in India: All patient records are stored on servers located in India. No data is transferred outside the country.
✓ DPDP Act Compliant: Under the Digital Personal Data Protection Act 2023, you can request deletion of your records at any time by contacting support.
Book Your Test
Enter your details and we'll connect you within 15 minutes.
