Skip to main content
DNA Labs India

FISH: BCL6 (3q27) Gene Rearrangement Test

DNA Labs India | ISO 9001:2015 Certified

FISH: BCL6 (3q27) Gene Rearrangement Test

Short Name: BCL6 FISH

Also known as: BCL6 gene rearrangement FISH, 3q27 FISH, BCL6 break-apart FISH

FISH: BCL6 (3q27) Gene Rearrangement Test test available at DNA Labs India for ₹9,000. Uses Fluorescence in situ hybridization (FISH) on Tumor tissue (paraffin-embedded block) samples. Results in Reports are typically available within 7-8 days after the sample is received at the laboratory.. Free home collection in 300+ cities across India.

FISH🏠 Home Collection

🩺 Medically Reviewed By

Overview

The purpose of the FISH BCL6 (3q27) gene rearrangement test is to detect chromosomal translocations involving the BCL6 gene. This helps in diagnosing specific types of lymphoma, determining prognosis, and guiding treatment decisions. The test is particularly useful in distinguishing between different subtypes of DLBCL and follicular lymphoma, as BCL6 rearrangement is associated with more aggressive disease and may influence therapy choices.

Test Code
6042
CPT Code
88271, 88275
ICD Code
C83.3, C82.9
Price
₹9,000
Sample Type
Tumor tissue (paraffin-embedded block)
Result Time
Reports are typically available within 7-8 days after the sample is received at the laboratory.
Fasting Required
No
Method
Fluorescence in situ hybridization (FISH)
Step 1

Sample Collection

No special preparation is required. A doctor's prescription is mandatory. Inform your doctor about any medications you are taking.

Method: Biopsy or surgical resection

Step 2

Laboratory Analysis

The sample is collected via biopsy procedure by a qualified healthcare professional. The procedure may cause minor discomfort.

Step 3

Report Delivery

No specific aftercare is required. You can resume normal activities immediately after sample collection.

Timeline: Reports are typically available within 7-8 days after the sample is received at the laboratory.

Patient Instructions

1
Before the Test:No special preparation is needed. Ensure you have a valid doctor's prescription. Inform your doctor about any ongoing treatments.
2
During the Test:The test is performed on a tissue sample obtained from a biopsy. The procedure is performed by a healthcare professional and may take a few minutes.
3
After the Test:You can resume normal activities immediately. Results will be available within 7-8 days and will be shared via your preferred mode of communication.

About This Test

Who Should Get This Test

The purpose of the FISH BCL6 (3q27) gene rearrangement test is to detect chromosomal translocations involving the BCL6 gene. This helps in diagnosing specific types of lymphoma, determining prognosis, and guiding treatment decisions. The test is particularly useful in distinguishing between different subtypes of DLBCL and follicular lymphoma, as BCL6 rearrangement is associated with more aggressive disease and may influence therapy choices.

How to Prepare

  • Tissue sample must be fixed in formalin and embedded in paraffin
  • Provide a minimum of 5 unstained sections (4-5 microns thick) on charged slides
  • Include a copy of the pathology report if available
  • Ensure the sample is properly labeled with patient identification

Doctor's Notes

Reviewed by — MBBS, MD (Pathology) · Reg. No. 21521

"BCL6 rearrangement is a key prognostic marker in diffuse large B-cell lymphoma. FISH testing helps guide targeted therapy and risk stratification."

Last medically reviewed: September 7, 2026

Test Parameters & Specifications

Sample TypeTumor tissue (paraffin-embedded block)
Sample Volume1 tissue block or 5-10 unstained sections
ContainerParaffin block or slides in a sterile container
Collection MethodBiopsy or surgical resection

Sample Stability

Paraffin-embedded tissue blocks: stable at room temperature for years
Unstained slides: stable for up to 6 months at room temperature
Sample Rejection Criteria:
  • Inadequate tissue sample (less than 20% tumor cells)
  • Severely necrotic or autolyzed tissue
  • Improperly fixed or decalcified samples
  • Unlabeled or mislabeled samples

Understanding Your Results

The FISH BCL6 (3q27) gene rearrangement test results are reported as positive or negative. A positive result indicates the presence of a rearrangement involving the BCL6 gene, which is commonly seen in certain lymphomas. The result should be interpreted by a qualified pathologist in the context of clinical and histopathological findings.
📊

Negative

No BCL6 rearrangement detected. This suggests a lower likelihood of BCL6-associated lymphoma, but other genetic abnormalities may still be present.

📊

Positive

BCL6 rearrangement detected. This is associated with aggressive lymphomas such as DLBCL and may influence treatment decisions. Further testing may be recommended.

⚠️ When to Consult a Doctor:

Consult your oncologist or hematologist if you experience persistent symptoms such as enlarged lymph nodes, unexplained fever, night sweats, weight loss, or fatigue. Early diagnosis and treatment can significantly improve outcomes.

Limitations

  • FISH only detects specific rearrangements; other genetic abnormalities may be missed
  • Requires adequate tumor tissue; small biopsies may be insufficient
  • Results should be interpreted in conjunction with histopathology and clinical findings
  • Not a standalone diagnostic test for lymphoma

Risks & Considerations

  • Minor bleeding or infection at the biopsy site
  • Discomfort during the biopsy procedure
  • Rare risk of tissue damage

Interfering Factors

  • Poor tissue quality or necrosis
  • Insufficient tumor cells in the sample
  • Decalcification of bone marrow samples
  • Fixation artifacts

Compare With Similar Tests

TestFISH: BCL6 (3q27) Gene RearrangementFISH MYC (8q24) Gene RearrangementFISH BCL2 (18q21) Gene RearrangementFISH IGH (14q32) Gene Rearrangement
ComparisonFISH: BCL6 (3q27) Gene Rearrangement

Frequently Asked Questions

What is the cost of the FISH BCL6 (3q27) gene rearrangement test at DNA Labs India?
The test costs INR 9000, which includes home sample collection and report interpretation.
What sample is required for the FISH BCL6 test?
Tumor tissue obtained from a biopsy, typically a paraffin-embedded block or unstained slides.
How long does it take to get the results?
Reports are available within 7-8 days after the sample is received.
Is fasting required before the test?
No, fasting is not required for this test.
What is the purpose of the BCL6 FISH test?
It detects rearrangements of the BCL6 gene, which are associated with certain lymphomas, helping in diagnosis and treatment planning.
Is a doctor's prescription necessary?
Yes, a doctor's prescription is mandatory for this test.
Can home sample collection be arranged?
Yes, we offer free home sample collection for online bookings across major cities in India.
What does a positive BCL6 rearrangement result mean?
A positive result indicates the presence of a BCL6 gene rearrangement, which is often seen in aggressive lymphomas like DLBCL.
Are there any risks associated with the biopsy?
Minor risks include bleeding, infection, or discomfort at the biopsy site, but these are rare.
Is the test covered by insurance?
Insurance coverage varies; please check with your insurance provider. We also offer affordable self-pay options.
Can the test be done on a blood sample?
No, this test requires tumor tissue, not blood.
What is the turnaround time for reports?
Reports are typically delivered within 7-8 days from sample receipt.
Worried about the process? Our certified phlebotomists collect thousands of samples every month across India. The process takes under 5 minutes and is virtually painless. Questions? Message us on WhatsApp — we're here 7 days a week.

Related Tests

For Hospitals & Clinics

Reference Laboratory Services

We serve as a reference laboratory for hospitals and clinics across India. Send samples from your facility with same-day pickup, priority processing, and results delivered through our online portal. Competitive institutional pricing available.

LIMS Integration

Your Data Privacy

Your medical data is protected under Indian law.

Stored in India: All patient records are stored on servers located in India. No data is transferred outside the country.

DPDP Act Compliant: Under the Digital Personal Data Protection Act 2023, you can request deletion of your records at any time by contacting support.

Book Your Test

Enter your details and we'll connect you within 15 minutes.

🧬

Quick Connect

Enter your mobile number and we’ll connect you with the team.

+91

✅ Connecting you now...

🔒 Your number is used to respond to this request.