Interferon - Beta IgG MAID Test
Short Name: IFN-Beta IgG MAID
Also known as: IFN-Beta IgG Antibody Test, Interferon Beta Antibody Test
Interferon - Beta IgG MAID Test test available at DNA Labs India for ₹22,000. Uses Multianalyte Immunodetection (MAID) on Serum samples. Results in 2-3 weeks after sample receipt at the laboratory. Free home collection in 300+ cities across India.
🩺 Medically Reviewed By
Dr Pasupathy Arumugam
Consultant Pathologist · Reg: 21521
Last reviewed: September 7, 2026
Overview
To detect the presence of Interferon-Beta IgG antibodies in the blood for diagnosing autoimmune disorders like Multiple Sclerosis and Neuromyelitis Optica, and to monitor the effectiveness of interferon-beta therapy by identifying antibody development that may block treatment.
- Test Code
- 1118
- Price
- ₹22,000
- Sample Type
- Serum
- Result Time
- 2-3 weeks after sample receipt at the laboratory
- Fasting Required
- No
- Method
- Multianalyte Immunodetection (MAID)
Sample Collection
Collect sample at least 8 hours after Interferon injection. Verify medication (Avonex, Rebif, Betaseron) and provide dose & duration of therapy. Duly filled Test Send Out Consent Form (Form 35) is mandatory.
Method: Venipuncture
Laboratory Analysis
Standard venipuncture procedure performed by a trained phlebotomist. Inform the patient about the process and ensure comfort.
Report Delivery
Apply pressure to the needle site to stop bleeding. Label the sample correctly with patient details and store as per stability guidelines.
Timeline: 2-3 weeks after sample receipt at the laboratory
Patient Instructions
About This Test
Who Should Get This Test
To detect the presence of Interferon-Beta IgG antibodies in the blood for diagnosing autoimmune disorders like Multiple Sclerosis and Neuromyelitis Optica, and to monitor the effectiveness of interferon-beta therapy by identifying antibody development that may block treatment.
How to Prepare
- Sample must be collected at least 8 hours after interferon-beta injection
- Provide detailed information about the medication name, dose, and duration of therapy
- Complete and submit the Test Send Out Consent Form (Form 35) along with the sample
- Use a Serum Separator Tube (SST) for collection and ensure proper handling
Doctor's Notes
Reviewed by Dr Pasupathy Arumugam — MBBS, MD (Pathology) · Reg. No. 21521
"This test is crucial for monitoring antibody response to interferon-beta therapy in MS patients, helping tailor treatment plans and assess efficacy."
Last medically reviewed: September 7, 2026
Test Parameters & Specifications
Sample Stability
- Sample collected less than 8 hours after interferon injection
- Incorrect sample type or container (non-SST tubes)
- Inadequate sample volume (less than 1 mL)
- Missing or incomplete consent form
- Improper labeling or storage of sample
Understanding Your Results
Positive
Indicates the presence of IgG antibodies to interferon-beta, which may neutralize the therapeutic effect of interferon-beta therapy in patients with MS or NMO. Clinical correlation is advised.
Negative
No detectable IgG antibodies to interferon-beta were found, suggesting no significant antibody response that would interfere with therapy. Continue monitoring as per clinical guidelines.
Consult a neurologist if you experience symptoms of MS or NMO such as numbness, vision problems, or balance issues, or if you are on interferon-beta therapy and suspect reduced treatment effectiveness due to antibody development.
Limitations
- ⚠This is a screening test and may require confirmatory testing for definitive diagnosis
- ⚠False positives can occur due to cross-reactivity or other autoimmune conditions
- ⚠Does not quantify antibody titer or assess neutralizing capacity directly
- ⚠Results should be interpreted in conjunction with clinical symptoms and other diagnostic tests
Risks & Considerations
- ●Minor bruising or pain at the needle insertion site
- ●Very low risk of infection
- ●Fainting or dizziness during blood draw
Interfering Factors
- ●Timing of sample collection relative to interferon injection (must be at least 8 hours post-injection)
- ●Recent infections or vaccinations that may affect immune response
- ●Concurrent use of other immunosuppressive medications
Compare With Similar Tests
| Test | Interferon - Beta IgG MAID Test | MRI Brain and Spine | Cerebrospinal Fluid (CSF) Analysis | Visual Evoked Potential (VEP) Test | Sensory Evoked Potential (SEP) Test |
|---|---|---|---|---|---|
| Comparison | Interferon - Beta IgG MAID Test | Imaging test to detect structural changes like lesions in the central nervous system, commonly used in MS diagnosis. | Tests for oligoclonal bands and other markers in cerebrospinal fluid, aiding in MS diagnosis. | Measures nerve conduction in visual pathways, helping assess demyelination in MS. | Assesses sensory nerve function, useful in evaluating neurological damage in MS and NMO. |
Frequently Asked Questions
What is the Interferon-Beta IgG MAID Test?
Why is this test performed?
What is the cost of the Interferon-Beta IgG MAID Test in India?
How is the test conducted?
What symptoms indicate the need for this test?
How should I prepare for the test?
What does a positive result mean?
What does a negative result mean?
Is home collection available for this test?
How long does it take to get results?
Are there any risks associated with the test?
Can this test monitor treatment effectiveness?
Related Tests
ANCA (Antineutrophil Cytoplasmic Antibodies) IFA Test
₹1,989ANCA (Anti Neutrophil Cytoplasmic Antibodies) Positive Reflex to ANCA-MPO & ANCA-PR3 Test
₹5,000ANCA (Antineutrophil Cytoplasmic Antibodies) IFA in Dilutions Test
₹5,000Anti-ss DNA Antibody Test
₹3,500ANCA (Anti-Neutrophil Cytoplasmic Antibodies) Extended Profile IgG Test
₹9,500Anti-ds DNA Antibody Crithidia IFA in Dilutions Test
₹4,500Reference Laboratory Services
We serve as a reference laboratory for hospitals and clinics across India. Send samples from your facility with same-day pickup, priority processing, and results delivered through our online portal. Competitive institutional pricing available.
Your Data Privacy
Your medical data is protected under Indian law.
✓ Stored in India: All patient records are stored on servers located in India. No data is transferred outside the country.
✓ DPDP Act Compliant: Under the Digital Personal Data Protection Act 2023, you can request deletion of your records at any time by contacting support.
Book Your Test
Enter your details and we'll connect you within 15 minutes.
