Skip to main content
DNA Labs India

HLA Pre-Transplant Workup Panel 2 Test

DNA Labs India | ISO 9001:2015 Certified

HLA Pre-Transplant Workup Panel 2 Test

Short Name: HLA Pre-Transplant Panel 2

Also known as: Human Leukocyte Antigen Typing, HLA Panel 2 Test, Transplant Compatibility Test

HLA Pre-Transplant Workup Panel 2 Test test available at DNA Labs India for ₹23,985. Uses Complement Dependent Cytotoxicity with DTT treatment, Reverse SSOP - Luminex, Luminex X-Map technology, Flow cytometry on Whole blood samples. Results in 10-12 business days. Free home collection in 300+ cities across India.

Nephrologist🏠 Home Collection

🩺 Medically Reviewed By

Overview

The primary purpose of the HLA Pre-Transplant Workup Panel 2 Test is to evaluate the compatibility between potential organ donors and recipients. By identifying HLA antigens, the test helps predict the risk of graft rejection and graft-versus-host disease, ensuring that transplants have the highest chance of success.

Test Code
819
Price
₹23,985
Sample Type
Whole blood
Result Time
10-12 business days
Fasting Required
No
Method
Complement Dependent Cytotoxicity with DTT treatment, Reverse SSOP - Luminex, Luminex X-Map technology, Flow cytometry
Step 1

Sample Collection

Obtain doctor's prescription on letterhead with photographs of recipient and donor, and signed consent form (Form 33). No fasting required.

Method: Venipuncture

Step 2

Laboratory Analysis

Blood samples collected via venipuncture into specified tubes: ACD, EDTA, and Sodium Heparin.

Step 3

Report Delivery

Label samples properly and ship at room temperature. Do not refrigerate or freeze.

Timeline: 10-12 business days

Patient Instructions

1
Before the Test:Ensure all required documents are submitted. No special preparation needed.
2
During the Test:Blood draw from donor; process may take time due to multiple tubes.
3
After the Test:Results available in 10-12 days; consult genetic counselor for interpretation.

About This Test

Who Should Get This Test

The primary purpose of the HLA Pre-Transplant Workup Panel 2 Test is to evaluate the compatibility between potential organ donors and recipients. By identifying HLA antigens, the test helps predict the risk of graft rejection and graft-versus-host disease, ensuring that transplants have the highest chance of success.

How to Prepare

  • Ensure all documentation is complete
  • Use correct tubes as specified
  • Maintain sample at room temperature during transport

Doctor's Notes

Reviewed by — MBBS, MD (Biochemistry) · Reg. No. 21504

"HLA Pre-Transplant Workup Panel 2 is essential for evaluating compatibility between donors and recipients, minimizing the risk of transplant rejection and improving outcomes."

Last medically reviewed: September 7, 2026

Test Parameters & Specifications

Sample TypeWhole blood
Sample Volume12 mL in ACD tubes, 4 mL in EDTA tube, 4 mL in Sodium Heparin tube
ContainerYellow Top (ACD), Lavender top (EDTA), Green Top (Sodium Heparin)
Collection MethodVenipuncture

Sample Stability

Room Temperature24 hours
RefrigeratorNot Applicable
FrozenNot Applicable
Sample Rejection Criteria:
  • Insufficient sample volume
  • Hemolyzed or clotted samples
  • Missing doctor's prescription or consent form
  • Incorrect sample containers

Understanding Your Results

Results indicate the degree of HLA matching between donor and recipient. A higher match reduces the risk of transplant rejection.
📊

Lower risk of rejection, suitable for transplant

📊

Higher risk of rejection, may require additional immunosuppression or alternative donors

⚠️ When to Consult a Doctor:

Consult your nephrologist or transplant specialist if you are considering an organ transplant or have received test results indicating incompatibility.

Limitations

  • May not detect all HLA variants
  • Results are dependent on sample quality
  • Requires expert interpretation

Risks & Considerations

  • Minor bruising at blood draw site
  • Rare risk of infection
  • No significant long-term risks

Interfering Factors

  • Recent blood transfusions
  • Presence of autoantibodies
  • Sample handling errors
  • Contamination during collection

Compare With Similar Tests

TestHLA Pre-Transplant Workup Panel 2 TestHLA Single Antigen TestCrossmatch Test
ComparisonHLA Pre-Transplant Workup Panel 2 Test

Frequently Asked Questions

What is the HLA Pre-Transplant Workup Panel 2 Test?
It is a test to assess compatibility between organ donors and recipients by identifying HLA antigens.
Why is this test necessary before a transplant?
To reduce the risk of transplant rejection by ensuring donor-recipient compatibility.
What samples are required for this test?
Whole blood from the donor in ACD, EDTA, and Sodium Heparin tubes.
How long does it take to get results?
Results are typically available within 10-12 days.
Is fasting required for this test?
No, fasting is not required, but doctor's prescription and consent are mandatory.
What is the cost of the test?
The test costs INR 23985 at DNA Labs India, including consultation.
Is home collection available?
Yes, free home sample collection is available in many cities across India.
What methods are used in this test?
Methods include Complement Dependent Cytotoxicity, Luminex technology, and flow cytometry.
How should samples be shipped?
Samples should be shipped at room temperature; do not refrigerate or freeze.
What documents are needed for the test?
Doctor's prescription on letterhead with photographs of donor and recipient, and signed consent form (Form 33).
Can this test be done for any organ transplant?
Yes, it is used for solid organ transplants like kidney, liver, heart, etc.
What if the results show low compatibility?
Consult your transplant specialist to discuss alternative donors or additional immunosuppression strategies.
Worried about the process? Our certified phlebotomists collect thousands of samples every month across India. The process takes under 5 minutes and is virtually painless. Questions? Message us on WhatsApp — we're here 7 days a week.

Related Tests

For Hospitals & Clinics

Reference Laboratory Services

We serve as a reference laboratory for hospitals and clinics across India. Send samples from your facility with same-day pickup, priority processing, and results delivered through our online portal. Competitive institutional pricing available.

LIMS Integration

Your Data Privacy

Your medical data is protected under Indian law.

Stored in India: All patient records are stored on servers located in India. No data is transferred outside the country.

DPDP Act Compliant: Under the Digital Personal Data Protection Act 2023, you can request deletion of your records at any time by contacting support.

Book Your Test

Enter your details and we'll connect you within 15 minutes.

🧬

Quick Connect

Enter your mobile number and we’ll connect you with the team.

+91

✅ Connecting you now...

🔒 Your number is used to respond to this request.